{"product_id":"ubiquiti-eth-sp-g2-ethernet-surge-protector-gen-2","title":"Ubiquiti ETH-SP-G2 Ethernet Surge Protector Gen 2","description":"\u003cp\u003eThe Ubiquiti ETH-SP-G2 Ethernet Surge Protector Gen 2 is a passive inline surge protector designed to shield outdoor network devices from electrostatic discharge and voltage spikes. It handles both PoE and non-PoE equipment running up to 2.5 Gbps and requires no power source, making it straightforward to deploy in exposed locations.\u003c\/p\u003e\u003ch5\u003eWhy This Product\u003c\/h5\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiverts damaging surges to ground safely\u003c\/strong\u003e — ESD and transient voltage attacks are absorbed and discharged harmlessly rather than passing through to connected devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorks with PoE and standard Ethernet alike\u003c\/strong\u003e — Two passive RJ45 connections support both powered and unpowered devices without any active components or power requirement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated for harsh outdoor conditions\u003c\/strong\u003e — IPX5 weatherproofing and operating range of −30 to 65° C means it remains effective in rain, snow and temperature swings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandles modern network speeds\u003c\/strong\u003e — Data line protection extends to 2.5 Gbps, covering current and near-future Ethernet deployments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch5\u003eAt a Glance\u003c\/h5\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin-bottom:10px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003ePassive surge protector, 2 RJ45 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eData line protection\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUp to 2.5 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eDischarge current\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 kA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eWeatherproofing\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eIPX5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e−30 to 65° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch5\u003eCompatibility\u003c\/h5\u003e\u003cul\u003e\n\u003cli\u003e✓ Any outdoor Ethernet device running at 1 Gbps or below, including PoE-powered access points, cameras and bridges.\u003c\/li\u003e\n\u003cli\u003e✓ 2.5 GbE equipment, provided surge exposure is the primary concern.\u003c\/li\u003e\n\u003cli\u003eNote: Indoor-only installations do not warrant the cost unless surge risk from external cabling is documented.\u003c\/li\u003e\n\u003cli\u003e✗ 10 GbE networks; data line protection maxes out at 2.5 Gbps.\u003c\/li\u003e\n\u003cli\u003e✗ Devices requiring active impedance matching or signal conditioning; this is purely passive surge diversion.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch5\u003eBest For \/ Trade-offs\u003c\/h5\u003e\u003cp\u003e\u003cstrong\u003eBest for:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOutdoor WiFi and cellular sites where lightning or nearby electrical activity poses a regular risk.\u003c\/li\u003e\n\u003cli\u003eRemote surveillance networks running PoE cameras in exposed locations.\u003c\/li\u003e\n\u003cli\u003eEthernet runs with significant external cable exposure, such as building-to-building links.\u003c\/li\u003e\n\u003cli\u003eBudget-conscious deployments needing ESD protection without active power or monitoring overhead.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTrade-offs:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHigh-speed data centers or servers\u003c\/b\u003e requiring 10 GbE or greater connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironments requiring a warranty or SLA\u003c\/b\u003e on protected device replacement in the event of a surge event.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInstallations where monitoring or alerting on surge events is mandatory.\u003c\/b\u003e This device provides no feedback or logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIndoor patched networks\u003c\/b\u003e with minimal external conductor exposure and no documented ESD history.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cp\u003eESD protection for outdoor high-speed networks.\u003c\/p\u003e\u003cp\u003eThe ETH-SP-G2 is engineered to protect any Power-over-Ethernet (PoE) or non-PoE device with connection speeds of up to 1 Gbps.\u003c\/p\u003e\u003cp\u003eTwo passive, surge-protected RJ45 connections provide maximum equipment compatibility. Damaging electrostatic discharge attacks and surges are diverted to the ETH-SP-G2 and safely discharged into the ground, so network devices are protected.\u003c\/p\u003e\u003ch5\u003eSpecifications\u003c\/h5\u003e\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin-bottom:10px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eUbiquiti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eNetworking interfaces\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e(2) RJ45 female connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003ePoE support\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003ePower required\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eNone (passive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin-bottom:10px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eESD\/EMP protection\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eAbsorbing transient current with response to surge voltage from 100V\/s to 1kV\/µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eDC spark-over voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e90V @ 100V\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eMax. impulse spark-over voltage\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e700V @ 1kV\/µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eDischarge current\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 kA+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eMax. insulation resistance\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e1G ohm @ 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eMax. capacitance\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e1.0 pF @ 1 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin-bottom:10px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eWeatherproofing rating\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003eIPX5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eEnclosure material\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eAmbient operating temperature\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e−30 to 65° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eAmbient operating humidity\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e10 to 90% noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003ePhysical\u003c\/strong\u003e\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;margin-bottom:10px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e91 x 61 x 32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;font-weight:bold;width:35%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:8px 12px;border:1px solid #ddd;\"\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Ubiquiti","offers":[{"title":"Default Title","offer_id":55667595379064,"sku":"UBI-1287","price":19.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/9119\/7218\/files\/62caf686-2476-4da0-be1e-e19887698024.png?v=1789815726","url":"https:\/\/tech-syndicate.co.uk\/products\/ubiquiti-eth-sp-g2-ethernet-surge-protector-gen-2","provider":"Tech Syndicate","version":"1.0","type":"link"}